BINSFELD ENGINEERING INC.

Specifications

 

TempTrak® RT416-PB Specifications


ROTOR

Number of Sensors: 6
Sensor connection: M3 set screw terminals with 2.38mm hole for ferrule access
Input Sensor Type: PT1000 RTD (1000 Ω at 0° C, α =.00385), standard
Sensor Range: 0-300° C
Speed: 10,000 RPM
Operating Temperature: 0-85° C

STATOR

I/O Connectors: 3-Conductor pluggable screw terminal
Status Indicator Lights: One for power and one for data
Operating Temperature: 0-85° C

Controller

Supply Voltage: 24 VDC (±5 VDC)
Supply Current: 500 mA maximum, 250 mA nominal, 1000 mA fuse protected
Supply Connector: 2-conductor pluggable screw connector
Communication Connection: DB-9F with standard Profibus pin-out) for operation as Profibus-DP slave; (DIP switch for node address setting)
Operating Temperature: 0-70° C
System Accuracy: ±0.5° C (maximum over ambient operating range for 0-300°C RTD range)

Specifications subject to change without prior notification.