ERROR CODES

DIAGNOSTICS FOR RT300/RT310  ROTARY TEMPERATURE TRANSMITTER SYSTEMS 

POWER STATUS

Stationary and rotary power in spec

CORRECTIVE ACTION:
No action required.

Rotary power out
of spec

CORRECTIVE ACTION:
Check rotor/stator spacing coax connections.

Stationary power out of spec

CORRECTIVE ACTION:
Check power source

System not powered

CORRECTIVE ACTION:
Check power source, power connections.

Insufficient rotary power or data not received

(Rotor Reset Mode)

CORRECTIVE ACTION:
Check rotor/stator spacing, coax connections.

DATA STATUS

Digital Transmission is error-free

CORRECTIVE ACTION:
No action required.

Data not received

CORRECTIVE ACTION:
Check rotor/stator spacing coax connections.

RTD STATUS

No errors detected

CORRECTIVE ACTION:
No action required.

Rotary side error:
RTD Channel 1 out of range (including open or shorted)>

CORRECTIVE ACTION:
Check RTD, connections

Open circuit in 4-20mA loop on Channel 1

CORRECTIVE ACTION:

Check connections and continuity of current loop

BINSFELD ENGINEERING INC.

4571 W. MacFarlane Rd.
Maple City, MI 49664 USA

 231.334.4383
 Contact Us
ISO 9001:2015 Certified

TORQUETRAK

Binsfeld's Torque Measurement Systems measure true mechanical torque and power on rotating shafts. We also offer consultation, strain gaging and installation services.

TEMPTRAK

Binsfeld's Rotary Temperature Transmitter Systems provide accurate and reliable temperature control on heated godets and calendars. We also offer design and OEM services.

TORQUETALK NEWSLETTER

Sign-up to receive featured application stories, relevant news, tips, and new product release information for our torque measurement products.