Binsfeld the Torque Measurement Experts
Measure Torque and Power Measure Torque Strain

TorqueTrak 10K - Specifications

TX10K-S Strain Transmitter

Sensor Input:
Full (four-arm) Wheatstone Bridge strain gage (350Ω standard)
Bridge Input:
2.5 VDC, ±0.1%
Sensor Range:
User selectable per chart below (chart based on gage factor = 2.0):
  Full Bridge Full Bridge 1/4 Bridge
Transmitter 4 Active Arms 2.6 Active Arms 1 Active Arm
Gain (Torque or Bending) (Tension or Compression) (Single Gage)

16000 ±125 microstrain ±192 microstrain ±500 microstrain
8000 ±250 microstrain ±385 microstrain ±1000 microstrain
4000 ±500 microstrain ±769 microstrain ±2000 microstrain
2000 ±1000 microstrain ±1538 microstrain ±4000 microstrain
1000 ±2000 microstrain ±3077 microstrain ±8000 microstrain
500 ±4000 microstrain ±6154 microstrain ±16,000 microstrain
Sensor & Power Connection:
Screw terminal block
Transmitter Power Input:
7.0 to 18VDC (9V battery typical)
Transmitter Power Current:
Transmit Mode:     40 mA nom, 50 mA max with 350Ω bridge

Standby Mode:      4 mA nom, 5 mA max
Transmitter Battery Life:
24 hours in Transmit Mode (9V lithium, 350Ω bridge, 25°C)
Transmission Frequency:
903-925 MHz
Transmit Distance:
20 feet or more
G-force Rating:
3000 g's (steady state) (e.g. 6500 rpm on a 5 inch diameter shaft)
Operating Temperature:
-30° - 85°C(-22° - 185°F)
Size and Weight (without antenna):
1.00"x 1.63"x 2.50", 3 oz (25 mm x 41 mm x 64 mm, 85 grams)

RM10K Remote Control (for use with TX10K-S Strain Transmitter)

Control Functions:
Channel select; Gain/Range; Shunt Calibration 1 and 2; Power Standby
Transmit Type and Distance:
Infrared; up to 10 feet (for use when transmitter is not rotating)

RX10K Receiver

Voltage Output:
±10 VDC, field adjustable 0.25x to 4.0x
5-way binding posts (banana jacks)
Digital Output Connection:
RS232 type DB9 connector (cable provided for PC COM port)
Receiver Power Input:
12VDC nominal (10 - 18VDC acceptable), 300 mA max
(110VAC or 220VAC adapter provided)
Operating Temperature:
-20° to 70°C (-4° to 158°F)
Size and Weight:
2.88" x 5.75" x 8.50", 2 lbs (73 mm x 146 mm x 216 mm, 1 kg)

TT10K System

Resolution:
14 bits
Gain Error1:
±0.25%Reading (max), 25°C ambient
Gain Temperature Coefficient1:
±0.005%Reading/°C (max), 0 - 50°C ambient
Offset Error1:
±0.16%FS (max), 25°C ambient
Offset Temperature Coefficient1:
±0.004%FS/°C (max), 0 - 50°C ambient
Frequency Response2:
0 - 500 Hz (-3dB @ 500Hz)
Delay2:
4.2 msec, typical
Sample Transmission Rate:
2400 samples/sec
1TX10K Gain = 4000
2RX10K filter setting = 500Hz

Specifications are subject to change without notice.

For TorqueTrak 10K Specifications in PDF format, Click Here

 

If you do not have Acrobat Reader, please click the icon below to download it:

Visit TempTrak Site Map