BINSFELD ENGINEERING INC.

back to site
TorqueTrak 10K
Torque Range Calculator
Full Scale Torque
corresponds to 10V output from the RX10K receiver


mm
mm (enter 0 for solid shaft)
(supplied with gages)
(4 for full bridge)
volts
volts
N/mm2 (206800 for steel)
(0.3 for steel)
Scale TorqueTrak 10K Output
Optional


N·m (0.25 to 4.0 times Full Scale Torque; with no scaling, Tref = Tfs)
Set System Gain on RX10K receiver to this value
Verify the Output
Recommended


NOTE: Valid for 350 ohm strain gage only. Deviation in the actual Voltage Output or Displayed Value from the Calculated Output value with shunt applied is not an indication of overall system accuracy. Shunt is placed in parallel with one leg of the bridge, exaggerating error that is cancelled in the full bridge circuit. However, Voltage Output should be within +/-1% of the calculated value.
Torque & Power Conversions
kW
RPM
N-m
RPM
Equations
`"Full Scale Torque", T_(FS)=(V_(FS)*pi*E*4*(D_O^4 - D_I^4))/ (V_(exc)*GF*N*16000*(1+v)*G_(xmt)*D_O)`
`"System Gain", G_S = (T_(fs)/T_(ref)) * G_(xmt)`
`"Sensitivity", S = T_(ref)/10`
`"Voltage Output", V = (T/T_(ref)) * V_(fs)`